Herunterladen Inhalt Inhalt Diese Seite drucken

Sensor Cleaning; Cleaning The Sensors - Rimage Professional 2450 Benutzerhandbuch

Vorschau ausblenden Andere Handbücher für Professional 2450:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 23

Sensor Cleaning

16.1: Cleaning the Sensors

# Tools Required
Can of Compressed Air
1. Make sure the system is powered off and that there are no
active or pending production jobs.
2. Remove the print ribbon carrier and print ribbon. For specific
instructions, refer to the Change the Print Ribbon procedure on
the inside of the printer cover.
Print Ribbon Sensor
Tip: One end of the handle has a slot with a notch in it near
the end. This is the end that goes into the printer. (See below.)
Swab Handle
Swab
2004849_A
Upper Sensor
Lower Sensor
Notch
For more information visit
3. Locate the swab and handle in the Everest Cleaning Kit.
4. If necessary, remove the swab from the handle.
5. Position the slotted end of the handle in the print ribbon sensor. Refer
to the diagram to the left to see the locations of the sensors.
6. Position the can of compressed air's nozzle in the unnotched end of the
handle.
7. Blow compressed air into the end of the handle three times in two-
second intervals.
8. Repeat steps 5-8 for the upper and lower sensors.
rimage.com/support
16

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis