Verfügbare Sprachen

ERROR MESSAGES
Problem
No display
on console
Motor don't start
E1
E2
E3
E6
E7
E8
Running belt slip
Blockage of
running belt
If errors occur, which are not listed herewith or if listed errors cannot be solved, please contact the
customer service.
36
Check
1. Bad connection of signal cable
2. No power supply
3. Overload protector
4. Transformer blow
1. Bad installation of safety lock
2. Bad connection of power plug
3. Bad connection of wires
4. Controller is broken
5. Motor is broken
Display and controller communication
failed
No speed sensor signal received for
over 3 seconds
Overcurrent protection.
Motor current is too high
Sudden overspeed occurs
Computer error
Controller error
1. Running belt is too loose
2. Motor belt is too loose
1. Runnig board lubrication is not
enough
2. Running belt is too tight
Solution
1. Well connect the signal cable
again
2. Well plug the power cable again
3. Turn off and on switch again
4. Contact with customer service
1. Put safety lock correctly
2. Well connect motor wires or con-
tact with distributor
3. Well connect the signal cable
4. Contact with customer service
5. Contact with customer service
1. Well connect the signal cable
2. Check if cable has been damaged
from upper display to controller
The speed sensor position could be
shifted. Contact with customer ser-
vice.
1. Please turn off the power and turn
on again.
2. Please check if the user weight is
overloaded.
3. Check if running belt underneath
needs silicon oils lubrication
Controller could be defective.
Contact customer service
Change Computer
Controller could be defective.
Contact customer service
1. Adjust tightness of running belt
2. Contact customer service
1. Make lubrication of running belt
2. Adjust the tightness of running
belt