Performance limits

Sensor measuring range
Measuring accuracy:
in range from -55 to -10°C
in range from -10 to +85°C
in range from +85 to +125°C
Switching temperature
Switching accuracy (hysteresis)
Display can be flipped 180° with buttons
Min/max display
Sensor monitored for short-circuit
Sensor monitored for open circuit
Output cuts out when sensor malfunctions
Runs without requiring operator input or attendance
Setups for heating or cooling
LC display shows temperature settings, relay (power socket) on, sensor fault, heating,
cooling
Programmed switching thresholds kept even if mains power fails
Automatically restarts after power failure

Manufacturer's address

Schemel & Goetz GmbH & Co KG
Elektrogerätebau
Schreberstraße 14
D-63069 Offenbach am Main
Phone: +49 69 835748
Fax: +49 69 847181
email: info@schego.de
www.schego.de
-55.0 – +125.0°C
+/-2.0°C
+/-0.5°C
+/-2.0°C
-55.0 to +125.0°C (in increments of 0.1°C)
0.1 to +10.0°C
Manufacturer's address