9.1. GETTING STARTED

(1) Recording data in real time, in wave form.
1. Start by switching on the sound level meter and connecting it to the USB port of
2. Start the SL software
3. If connection succeeds, the program window displays the same value as the
4. Click  to start recording the data in real time. A curve appears in the real-time
5. Click  to stop recording.
(2) How do you save the data acquired in real time to a file?
1. Click the window of the curve you want to save to activate it, then select File/
2. A dialogue box opens to let you choose the name and format of the file to be

9. THE SL SOFTWARE

the PC using the cable.
integrating sound level meter. If connection fails, the window displays "No
Connection".
graph window.
Record in the main menu or click
recorded. You have a choice of three formats: binary (*.ghf), text (*.txt) and
Excel-compatible text (*.csv). Files in *.ghf format take less disc space than the
other two formats, but can be read only by The PC software. Text files can be
opened by the software and by any other word processor or text editor, such as
Word, Notepad, etc. Files in *.csv format can be opened by the SL software and
by Microsoft EXCEL.