Installation Instructions

Safety instructions

Warning! This must be read!
The laws, ordinances, directives and standards in force
in the country of use are to be followed (safety regulations,
proper recycling in accordance with the regulations, etc.)
Installation may only be carried out by a qualified elec-
trician. The minimum distances to other appliances and
units are to be observed.
Anti-shock protection must be provided by the installa-
tion, for example drawers may only be installed with a
protective floor directly underneath the appliance. The cut
surfaces of the worktop are to be protected against mois-
ture using a suitable sealant.
The sealant seals the appliance to the work top with no
gap. When building in, protect the underside of the ap-
pliance from steam and moisture, e.g. from a dishwasher
or oven.
Avoid installing the appliance next to doors and under
windows. Otherwise hot cookware may be knocked off the
rings when doors and windows are opened.
Warning! Risk of injury from electrical current.
• The electrical mains terminal is live.
• Make electrical mains terminal free of voltage.
• Follow connection schematic.
min. 55
490+1
min. 55
14
600
750+1
R5
• Observe electrical safety rules.
• Ensure anti-shock protection by installing correctly.
• The appliance must be connected to the electrical sup-
ply by a qualified electrician.
• Loose and inappropriate plug and socket connections
can make the terminal overheat.
• Have the clamping connections correctly installed by
a qualified electrician.
• Use strain relief clamp on cable.
• In the event of single-phase or two phase connection,
the appropriate mains cable of type H05BB-F Tmax
90°C (or higher) must be used.
• If this appliance's mains cable is damaged, it must be
replaced by a special cable (type H05BB-F Tmax 90°C;
or higher).The latter is available from the Customer
Care Department.
A device must be provided in the electrical installation
which allows the appliance to be disconnected from the
mains at all poles with a contact opening width of at least
3 mm.
Suitable isolation devices include line protecting cut-
outs, fuses (screw type fuses are to be removed from the
holder), earth leakage trips and contactors.
Assembly