Herunterladen Diese Seite drucken

Electrical Connection - Danfoss PVED-CC 5 Serie Installationsanleitung

Werbung

Electrical Connection

AMP JPT Connector
Deutsch Connector
PVE LED Farver
PVE LED Colors
PVE LED Farben
PVE LED Couleurs
The colour of on board LED reflects status of S5 valve.
LED Color
Flashing between orange and green
Orange
Green
Flashing green
Flashing orange
Red
4
Pin no.
Connection / signal
1
Can_L
2
VBAT / U_DC
3
GND
4
Can_H
There is full electrical connection between
the connectors.
Pin no.
Connection / signal
1
Can_H
2
Can_L
3
VBAT / U_DC
4
GND
There is full electrical connection between
the connectors.
PVE software status
PVE is in bootloader / service mode
PVE is in disabled state and there are no (non-info type of) errors present
PVE is enabled and spool is at neutral position
Spool is steered outside of the dead band as a result of receiving a
non-zero setpoint through the CAN-BUS
A Warning, Critical or Severe error of is present in the system or the PVE is
in power save mode
Internal handshake aliveness communication fault or CAN controller
initializing failure or inability to recover from BUS-off
11072470 • Rev BB • Mar 2014
4
3
2
1
1
2
3
4
V310049.A
4
1
2
3
2
3
1
4
V310050.A
Safety Switch
Disabled
Disabled
Enabled
Enabled
Disabled
Disabled
© Danfoss, 2014-03

Werbung

loading