Herunterladen Diese Seite drucken

Danfoss PVED-CC 5 Serie Installationsanleitung Seite 2

Werbung

Technical Data
WWarning
2
Nominal (V
)
bat
Minimum (V
)
bat
Maximum (V
)
bat
Max ripple
Current consumption (operating@12 V)
Power consumption (operating@12 V)
Current consumtion (neutral - power safe)
Power consumtion (neutral - power safe)
Activation of solenoid valves by 9-11 V will give reduced valve performance.
>35.5 V and <9 V will shut down electronics.
Oil consumption
Supply
Function
Without
Pilot oil flow per PVED-CC neutral
voltage
With
Pilot oil flow
voltage
per PVED-CC
Oil viscosity
range
12 - 75 mm
Oil
min.
4 mm
/s [39 SUS]
2
viscosity
max.
460 mm
/s [2128 SUS]
2
Note: Max. start up viscosity 2500 mm
Filtering
Max. allowed degree of
Filtering in the
contamination (ISO 4406,
hydraulic system
1999 version): 18/16/13
PCB temperature
0 → 85˚C
range
[32 → 185˚F]
PCB
min
-30˚C [-22˚F]
temperature
max avarage 85˚C [185˚F]
max instant
100˚C [212˚F]
WWarning
By operation with PCB temperature below 0°C the transition to fault mode due to spool
monitoring is delayed according to product specification.
Hvis den indbyggede temperatursensor på printet måler mere end 100°C [212˚F] som øjeblikkelig
temperatur eller mere end 85°C [185˚F] som gennemsnitstemperatur vil PVED-CC gå i fejltilstand.
If the build in temperature sensor on the PCB shows more than a 100°C [212˚F] as instant
temperature or more than 85°C [185˚F] as average temperatur the PVED-CC will go into a fault
state.
Falls der eingebaute Temperatursensor auf der Leiterplatte eine aktuelle Temperatur von über
100°C [212˚F] oder eine Durchschnittstemperatur von über 85°C [185˚F] misst, wird das PVED-CC
Modul in den Fehlerzustand gehen.
En cas où la sonde de temperature integrée enregistre une température instantanée supérieure à
100°C [212˚F] ou une température moyenne supérieure à 85°C [185˚F], le PVED-CC se met en
mode erreur.
11072470 • Rev BB • Mar 2014
Supply Voltage
Power Consumption
locked
one actuation
(neutral → max.)
continuous
actuations
Oil temperature
/s [65 - 347 SUS]
2
Oil
temperature
/s
2
Ambient temperature
Operation
Storage
11 - 32 V
9.5 V
33.5 V
5%
560 mA
6.7 W
80 mA
1 W
PVED-CC
0 l/min
[0 US gal/min]
0 l/min
[0 US gal/min]
0.001 l
[0.024 US gal]
0.8 l/min
[0.211 US gal/min]
30 → 60˚C [86 →
range
140˚F]
min.
-30˚C [-22˚F]
max.
90˚C [194˚F]
-30° → 60°C [-22° → 140°F ]
-40° → 60°C [-40° → 140°F ]
© Danfoss, 2014-03

Werbung

loading