• Avoid the installation in rooms with presence of common ventilation ducts, hoods with or without extractor, gas
devices of type B, heat pumps or the presence of devices whose simultaneous operation can cause depression in
the room (Ref. Standard UNI 10683/98)
• Make sure that the flue and the pipes to which the device will be connected are suitable for the operation of the
same.
• Always leave the recommended air pocket between the monoblock and the walls according to the model. (see
Picture 14 - Picture 16).
• Establish the type of ventilation (natural or forced) see CHAP. 6.
• By means of the adjustable feet and using a level make sure that the device is perfectly leveled to allow a correct
sliding of the door.
It is recommended that you have your local usual chimney sweeper check both the connection to the stack and the
sufficient air inflow for the combustion in the installation room.
4.

FIRE-FIGHTING SAFETY MEASURES

While installing the device, it is necessary to respect the following safety measures(see Picture 2):
a) In front of the monoblock there must not be any flammable object or construction material sensitive to heat
within a distance of 80 cm;
b) Should the device be installed on a floor made of not completely refractory material, it is necessary to foresee
a fire-resistant foundation, for example a steel footboard (dimensions according to the local regulations.
Warn children that the device becomes very hot and that it must not be touched.
The monoblock must work exclusively with inserted ash drawer.
Protection of the floor
with incombustible material
Flooring in
combustible material
solid combustion residuals (ashes) must be collected in an air-tight and fire-resistant container. The device must
never be switched on when there are gaseous emissions vapors (for example glue for linoleum, gasoline etc.). Do not
deposit flammable materials close to the same.
4.1.

FIRST-AID MEASURES

Should any fire arise in the stack or in the flue:
a) Close the feeding door.
b) Close the registers of combustion air
c) Extinguish the fire using carbon dioxide fire-fighting means (CO
d) Seek immediate intervention of FIRE BRIGADE.
DO NOT EXTINGUISH FIRE USING WATER JETS
When the flue does not burn any more please arrange an examination by a specialist in order to find possible cracks
and permeable points.
6099751 Rev.04 – EN
A
A= Side limit of the protected area (A=H+20 cm=> 40 cm)
B= Front limit of the protected area (B=H+30 cm=> 60 cm)
Height of the hearth
surface from the
ground
H
B
dust).
2
Picture 2
19