CHIMNEY CAPS - DISTANCES AND POSITIONING UNI 10683/98
Inclination of the
Distance between the roof ridge and the
roof
15°
30°
45°
60°
22
(1) In case of flues side by side, a chimney cap must be higher
than the other one of at least 50 cm in order to avoid pressure
transfers between the flues themselves.
10 m
>A
H min.
(1)Asse colmo
α
stack
A (m)
< 1.85 m
> 1.85 m
< 1.50 m
> 1.50 m
< 1.30 m
> 1.30 m
< 1.20 m
> 1.20 m
(1) The chimney cap must not show hindrances within 10 m
from walls, pitches and trees. Otherwise raise it of at least 1
m over the hindrance.
The chimney cap must exceed the ridge of the roof of at
least 1 m.
> _ A
0,5 m
(2)Tetto
Minimum height of the stack (measured from
the outlet)
Monoblocco Ghisa 750
(1) Ridge axis
(2) Roof
H (m)
0.50 m above the roof ridge
1.00 m from the roof
0.50 m above the roof ridge
1.30 m from the roof
0.50 m above the roof ridge
2.00 m from the roof
0.50 m above the roof ridge
2.60 m from the roof
6099751 Rev.04 – EN
Picture 8