Verfügbare Sprachen

Wiring diagram installation of switches/buttons
Mains
Attention: Make sure that the wiring of the motor control is not mixed up (brown=up, black=down) when inserting the cables
for the switch/button (up/down)to the lift. Use only certified protected cables.
Safety instructions:
• The switches and controls must not enable simultaneous up and down commands. This would damage the unit.
Only use mechanical or electrical switches!
• There must be an interval of more than 0.5 seconds between an up and down command. Otherwise high voltage could
damage the motor.
• Condensor motors are suitable only for short time operaqtion (approx. 4 minutes). If the motor is overheated during a
test drive or when in operation, it is switched off automatically.In such a case let the motor cool down approx. 15 minutes.
• Check whether the two carrying ropes are of the same length and are wound up tightly and orderly on the shaft of the
motor.
• Make sure that the projector is brought in upward position only after it has been switched off and has cooled down.
• If the lift is operated by a media control, the programming of the media control must be done likewise and the safety
instructions must be observed.
Attention: The parallel wiring of several condenser motors is not allowed (ceiling lift, electrical screen...).
In such a case use a splitter with separate inputs for each motor.

4.8 Safety power cut

The ceiling lift is equipped with a safety power cut. The condenser motor stops automatically, if the movement of the lift is
obstructed and the carrying rope is no longer under tension.

5. Maintenance

The safety and reliability of the ceiling lift must be checked at least once a year. The check comprises all mechanical parts,
steel ropes, cable connections, screws. Especially the steel ropes must not be worn out, broken or bent. The two carrying
ropes must run freely and simultaneously and should be free of any other damages. Damaged parts must be exchanged
immediately!

6. First aid in case of malfunctions

➡ Lift does not react to UP or DOWN command, no function
• Check the micro switch of the rope control: both micro switches on the carrying rope must be inserted in the tightened
rope.
Splitter
building
green/yellow
blue
black
Cable between splitter
and socket at least 6-pin
(e. g. NYM 7x1.5 mm
Wall switch/button
e. g. 5944 000 002
Safety switch
blue
gn/ye
green/yellow
blue
bl
brown
br
black
black
2
)
Motor
Socket for
Socket on lift
button/
switch (building)
27