3.5 Mounting on false ceiling

If the ceiling lift is not mounted directly on a real ceiling the extension set with stabilizers is needed (7466 000019).
To guarantee a sturdy construction additional props may be necessary.
Attention: Before mounting the extension set the two stabilzers

4. Connection to mains

The motor of the ceiling lift is a reversal single phase condensor motor, similar to the ones used for shutters, with integrated
electronic stop switches, brake and transmission.
Connection the unit to the mains must only be done by an electrician. Never use damaged devices. Before mounting
the lift check the specifications on the lable with thoses of the local power supply. Do all mounting and maintenance
works with the power supply switched of.
The projector is connected to the mains via the provided wiring through the spiral cable guide
projector garage (see 3.1).

4.1 Connection to programming unit

Guide the 4-pin motor cable
Circuit diagram programming unit
Mains
PE N L
Ceiling lift
22
to the socket and connect the programming unit according to the following circuit diagram.
3a
Switch for projetor
Switch for
control of safety rope
blue
Projector
on the upper frame of the lift.
a
a
blue
black
black
brown
brown
yellow/green
yellow/green
Power socket
Programming unit
ceiling lift
7466 000 100 or
7466 000 101
to the mains socket of the
5a
Mains