Switch no.
MSW10-2
MSW10-3
MSW10-4
Old Command
MSW10-5
Buzzer Event
MSW10-6
Buzzer Sound
MSW13-1
Security/Target
MSW13-5
BT Device Scan
MSW13-6
Auto Reconnect
Note:
*1: If print data is very dense, the print head is hot, data transmission is slow, or some other conditions,
the motor and printing may occasionally stop which causes white stripes in the printout. To print
high-density data, set MSW2-3 (Spool Print) to ON to reduce striping, although this increases the
time before printing starts.
For a serial interface, increase the transmission speed to prevent the motor from stopping.
*2: The values for memory switches MSW7-X are only effective when DIP switch no. 1 is set to OFF .
*3: Liner-free model specifications
*4: For liner-free model, partial cut only
Function
Initial setting
Print Speed
Level 9
ACK Timing
Before Busy Before Busy, Same Period, After Busy
Invalid
Not by
C.Open
Low/All
Discoverable No Response, Discoverable
Level 1, Level 2, Level 3, Level 4, Level 5, Level 6,
Level 7 , Level 8, Level 9
Invalid, CBM1, CBM2
All Event/Error, Not by C.Open, Not by C.Open/PE
Tone 2
Tone 1, Tone 2, Tone 3, Tone 4
Low/All, Mid/All, Mid/Paired only, Hi/All, Hi/Paired
only
Valid
Invalid, Valid
— 62 —