Failure: The green LEDs are lit, but the pumps
connected do not operate.
Cause: The pump is defective.
Remedy: Check the parts, and repair or replace, if
and when necessary.
Cause: The Multicontroller is defective.
Remedy: Check the Multicontroller, and repair,
if and when necessary. Clean any corroded
contacts on the sockets.
Failure: The Multicontroller operates with a very
low output only.
Cause: The output on the driver has not been set
to 100 per cent.
Remedy: Turn the "Power" adjusting screw on the
pump clockwise to stop, i.e. to 100 per cent.
Failure: The LED on the Multicontroller are lit
correctly, but the pumps connected operate at
100 % all the time.
Cause: The connecting cable between the
Multicontroller and the driver is defective.
Remedy: Replace connecting cable 7092.30.
Disfonctionnements : La LED verte est allumée,
mais la pompe raccordée ne fonctionne pas.
Raisons: Pompe défectueuse.
Solutions: Vérifiez les différentes pièces, réparez
ou renouvelez le cas échéant.
Raisons: Multicontroller défectueux.
Solutions: Contrôlez le Multicontroller ou réparez
le cas échéant. Nettoyez éventuellement la
corrosion sur les contacts des prises.
Disfonctionnements : Le Multicontroller ne
délivre qu'une puissance relativement limitée.
Raisons: La puissance au niveau du Driver n'est
pas à 100%.
Solutions: Tournez le potentiomètre « POWER »
de la pompe jusqu'en butée à 100% dans le
sens horaire.
Disfonctionnements : Les LED sur Multicontroller
indiquent une puissance de sortie modulée.
Cependant, la pompe fonctionne toujours à
100% de sa puissance.
Raisons: Câble de liaison défectueux entre
Multicontroller et Driver.
Solutions: Remplacez le câble 7092.30.