„pulse" - example
Multicontroller 7095 and two Turbelle® electronic /
stream.
Set button (6) in such a way that the „pulse" LED
lights up.
Set adjustment knob (1a) to 30 % power.
Set adjustment knob (1b) to 100 % power.
Set adjustment knob (2a) to 40 % power.
Set adjustment knob (2b) to 80 % power.
Set the „pulse" adjustment knob to a pulse time of
1.5 seconds.
Connect one pump each to the socket of „channel 1"
(1.1) or (1.2) and to the socket of „channel 2" (2.1)
or (2.2).
Result:
The pump on „channel 1" varies its power between
30 % and 100 %.
The pump on „channel 2" varies its power between
40 % and 80 %.
The pulse cycle is defined at 1.5 seconds by means
of the adjustment knob (5).
« pulse » - exemple
Composants : Multicontroller 7095 et deux pompes
Turbelle® electronic / Turbelle® stream.
Choisissez la fonction « pulse » à l'aide de la
touche (6).
Positionnez le bouton (1a) sur 30%.
Positionnez le bouton (1b) sur 100%.
Positionnez le bouton (2a) sur 40%.
Positionnez le bouton (2b) sur 80%.
Avec le bouton « pulse », réglez un temps de
pulsation de 1,5 secondes.
Raccordez une pompe sur une prise (1.1) ou (1.2)
du canal « channel 1 » et une pompe sur une prise
(2.1) ou (2.2) du canal « channel 2 ».
Résultat :
La pompe du canal 1 varie sa puissance de 30% à
100%.
La pompe du canal 2 varie sa puissance de 40% à
80%.
La fréquence de pulsation est définie par le
bouton (5) à 1,5 secondes.