13 Anhang
Command
Response
aD0!
a<value1><value2><value3><val
ue4><value5><CR><LF>
Measurement data and Format:
Stage value
– +ss.sss (m)
– +ss.sss (ft)
– +sssss (mm)
– +sss.ss (in)
Distance
– +dd.ddd (m)
– +dd.ddd (ft)
– +ddddd (mm)
– +ddd.dd (in)
Electronics temperature
– ttt.t (°C, °F, K)
Measurement reliability
– rrr (dB)
Device status
– eee (Errror code)
Example
Address = 0, Stage = 29,272m, Distance = 0,728m, Temperature = 25,4°C, reliability = 14dB, De-
vice Status = Good
Response : 0+29.272+0.728+25.4+14+0<CR><LF>
Address = 4, Stage = 14,887m, Distance = 0,113m, Temperature = 22,7°C, reliability = 14dB, De-
vice Status = M507 (Error in the device setting)
Response : 4+14.887+0.113+22.7+14+507<CR><LF>

13.4 Extended Commands

Command
aXRPOM!
aXWPOM<value1>!
aXRDU!
aXWDU<value1>!
aXRTU!
aXWTU<value1>!
aXRSR!
50
Response
a<value1><value2><CR><LF>
a<value1><value2><CR><LF>
a<value1><CR><LF>
a<value1><value2><CR><LF>
a<value1><CR><LF>
a<value1><CR><LF>
a<value1><value2><CR><LF>
Description
Send data (after aM!)
a: sensor address
<value1>: stage value:pss.sss
<value2>: distance value pdd.ddd
<value3>: electronics temperature pttt.t
<value4>: Measurement reliability prrr
<value5>: Device status eee
<CR><LF>
Description
Read Power Operation Mode
Write Power Operation Mode
Read distance unit
Write distance unit
Read temperature unit
Write temperature unit
Read stage reference
VEGAPULS C 21 • SDI-12