Setting The Hot Water Temperature; Setting The Heating Water Temperature; Requesting Current Data - Atag A Serie Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für A Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.2

Setting the hot water temperature

i
+
i
-
R
4.3

Setting the heating water temperature

i
+
i
-
R
4.4

Requesting current data

i
+
i
-
R
Press + or - of the
+
The display will show the set value while flashing;
Press + or – to change the set value.
Each change becomes active directly.
-
Hot water program OFF:
Press – until the lowest value is reached and then
press – again.
The display is showing -- and the upper
Switching on works in reverse order.
Press + or - of the
The display will show the set value while flashing;
+
Press + or – to change the set value.
Each change becomes active directly.
-
Heating program OFF:
Press – until the lowest value is reached and then
press – again.
The display is showing -- and the upper
Switching on works in reverse order.
Briefly press the i-button or scroll button to obtain
the following values:
+
A0 =
Supply water temperature
A1 =
Return water temperature
A2 =
Hot water temperature
-
A4 =
Flue gas temperature
(Only if a flue gas sensor is connected)
A5 =
Outside temperature
(Only if an outside sensor is connected)
A6 =
Water pressure
A9 =
Rpms of fan
To return to the standard view press ESC.
key;
key;
is off.
is off.
19