Rs485 i/o-modul 12 eingänge, 14 schaltausgänge, hutschienenmontage
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Function
The outputs can also be used as outputs for a square-
wave signal with variable frequency. In the module
configuration, the length of the pulse can be adjusted
(0 - 600 s). The repetition frequency (0 - 50 Hz) can be
selected via the value of the channel (operation). If a
pulse duration of 0 s is set, the selected frequency will
be directly transmitted (pulse/pause ratio 1:1).
The relay switching outputs are capable of switching
loads up to 30 V/0.8 A.
The extensive configuration options are available via
the WebUI user inferface of the Homematic central
control unit.
The configuration data is stored in a non-volatile
memory.
The module is mounted on a standard DIN rail within
distribution boards.