The second balancing process for the calibration starts when you
press the START button or close the wheel protector.
The display shown opposite appears after the balancing process.
Attach the calibration weight (100 g) to the outside of the wheel rim.
Press the START button again or close the wheel protector in order
to terminate the calibration process.
2.9.12.
Position the gauge to "0"
Press the key combination STOP + < 5 g
The display shown opposite will appear
Position the gauge to "100 mm"
Press the ALU button
The display shows [CAL] – [300]
Position the gauge to "300 mm". When doing so, position the
measuring tip to the outer edge of the entry cover.
Press the ALU button
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2020-03

Service calibration of the gauge in car mode

Manufacturer ATH-Heinl GmbH & CO.KG
- 32 -
/
/
+