Press the START button again or close the wheel protector in order
/
to terminate the calibration process.
2.9.10

Service calibration of the gauge in lorry mode

Position the gauge to "0"
Press the key combination STOP + < 5 g
The display shown opposite will appear
+
Position the gauge to "100 mm"
Press the ALU button
The display shows [CAL] – [300]
Position the gauge to "300 mm". When doing so, position the
measuring tip to the outer edge of the entry cover (be careful of
the recess!).
Press the ALU button
The display shows [CAL.] – [22.5]
This value can be changed using D+ / D-
Confirm with [ALU].
Then secure an appropriate wheel (e.g. 22.5") on the machine
Next, position the plunge on the edge of the wheel rim