Wireless DMX

For wireless data transmission you need a DMX-controller, a wireless transmitter and a wireless receiver or
devices with built-in wireless receiver. Please use the appropriate devices from the FUTURELIGHT range.
Please note: WDMX has priority over DMX!
The wireless receiver has an internal memory function. If the device is switched off and on again, the
receiver automatically logs onto the wireless transmitter.
Wireless receiver transmitter status LED:
WDMX status
WDMX status dot blinks: The wireless receiver is logged into the wireless transmitter. The DMX signal is
present and received.
No WDMX status dot: Not logged into a wireless transmitter (free).
Log out a wireless receiver:
To log out a wireless receiver, press and hold the ENTER button for 10 seconds.
The procedure for installing a wireless DMX system depends on the wireless transmitter being used. Please
refer to the instructions in the user manual of the corresponding device.
DMX Mode selection and setting the starting address
The Control Board allows you to assign the DMX fixture address, which is defined as the first channel from
which the LED IP CCR-600 QCL will respond to the controller.
Please press the UP or DOWN buttons in order to choose the desired DMX mode (d001: 4CH, F001: 5CH or
A001: 8CH) and press the ENTER button to confirm.
You can now set the desired address via the UP or DOWN buttons.
Please press the ENTER button to confirm.
Please press the MODE button in order to return to the main menu.
Please, be sure that you don't have any overlapping channels in order to control each LED IP CCR-600 QCL
correctly and independently from any other fixture on the DMX-chain. If several LED IP CCR-600 QCL are
addressed similarly, they will work synchronically.
Controlling:
After having addressed the device, you may now start operating it via your lighting controller.
Please see the following DMX protocol graphic for the respective channel values.
Note:
After switching on, the device will automatically detect whether DMX 512 data is received or not. If there is
data received at the DMX-input, a dot on the LED display will blink. If there is no data received, the dot will
not blink.
This situation can occur if:
- the XLR plug (cable with DMX signal from controller) is not connected with the input of the device.
- the wireless receiver is not logged in to the wireless transmitter or no wireless DMX signal is received.
- the controller is switched off or defective, if the cable or connector is defective or the signal wires are swap
in the input connector.