Before installation, please read and follow these instructions. An
incorrect installation could lead to serious injury. The product must
be installed by a qualified electrician. SOMFY's liability for defects
and damages is excluded if they were caused by disregard of the
instructions. Keep these instructions for future reference.
IT
Prima dell'installazione leggere attentamente queste istruzioni.
Un'installazione non corretta può causare gravi ferite. L'installazi o ne
deve essere eseguita da un elettricista qualificato. SOMFY non può
essere ritenuta responsabile per difetti o danneggiamenti causati
dal mancato rispetto di queste istruzioni.
Conservare queste istruzioni.
FR
Avant la mise en œuvre, veuillez lire et suivre les instructions de
sécurité ci-jointes. Une mauvaise installation peut conduire à de
graves blessures. Le produit doit être installé par un électricien
qualifié. SOMFY ne peut être tenue responsable des vices et des
dommages occasionnés par un non respect de ces instructions.
Conservez ces instructions pour toute intervention sur le produit.
SE
Före installation, läs noggrant igenom denna manual och följ
sedan instruktionerna. En felaktig installation kan medföra livsfara.
Produkten skall installeras av behörig elektriker. SOMFY's åtaganden
gäller ej om installation inte utförts enligt instruktionerna.
Spara manualen för framtida bruk.
CHARACTERISTICS: animeo KNX/EIB 4 AC Motor Controller
4 AC Motor Controller
WM Ref. 1860114
Supply voltage
220-240 V AC / 50/60 Hz
Supply voltage from EIB Bus
EIB-voltage 21 ... 30 V DC, SELV
Rated current consumption EIB
As
Stand-by current (primary)
26 mA
4 x 3.15 A, cos ϕ = 0,95
Max. motor current consumption
Supply voltage of group control input
LELV, 16 V DC
Supply voltage of local push buttons
SELV, 16 V DC
Terminals
Spring connectors
Terminal EIB
EIB bus terminal (black/red)
Running time per output (relay contact)
Max. 5 minutes
Fuse per output
4 x 3.15
Operating temperature
0 °C to 45 °C
Relative humidity
85 %
Material of housing
CC-ABS
Housing dimensions
180 x 255 x 63 mm
Degree of protection
IP 20
Protection class
II, corresponding to the installation
Automatic action
Typ 1.C micro interruption
Pollution degree
2
Rated impulse voltage
4 kV
Temperature of ball pressure test
75 °C
Conformity
CE by EN 60730-1
Magenta markiert = Information fraglich bzw. doppelt (hier: in Tabelle oder im unteren Text streichen?)
The Motor Controller is an electronic operated,
independently mounted control.
Looped-through PE-connection
Type 1 action
Pollution degree: 2
Rated impulse voltage: 4 kV
Temperature of the ball hardness test: 75 °C
NL
Lees voor het installeren eerst deze handleiding. Een onjuiste
installatie kan de apparatuur ernstig beschad ig en. Dit product
mag alleen door een deskundige aangesloten worden.
De SOMFY garantie is niet van toepassing als de aanwijzigingen
in deze handleiding genegeerd worden. Bewaar dit document
voor later gebruik.
NO
Før installasjon, les disse instrukser. Feil installasjon kan føre til
alvorlig skade. Installasjonen skal utføres av autorisert installatør.
SOMFY's ansvar for skader bortfaller hvis disse instruksjoner ikke
følges. Behold instruksjonene for fremtidige referanser.
DE
Vor Inbetriebnahme unbedingt die Sicherheits anwei sungen in
dieser Anleitung beachten. Die Haftung von SOMFY für Mängel und
Schäden ist ausgeschlossen, wenn diese auf Nichtbeachten der
Gebrauchs anweisung (falsche In stallation, Fehlbedienung, etc.)
beruhen. Errichten, Prüfen und Inbetriebsetzen der Anlage darf
nur von einer Fachkraft (lt. VDE 0100) durchgeführt werden!
Schalten Sie alle zu montierenden Anschlussleitungen spannungslos!
Treffen Sie Vor kehrungen gegen unbeab sichtigtes Einschalten!
FI
Ennen asennusta, ole hyvä ja lue ja seuraa näitä ohjeita.
Virheellinen asennus voi aiheuttaa vakavia vaurioita. Tuotteen
tulee asentaa valtuutettu sähköasentaja. SOMFYn vastuu virheistä
ja vaurioista poistuu, jos ne ovat aiheutuneet ohjeiden vastaisesta
toiminnasta. Säilytä nämä ohjeet.
DRM Ref. 1860116
220-240 V AC / 50/60 Hz
EIB-voltage 21 ... 30 V DC, SELV
per
EIB/KNX guidelines
As
per
EIB/KNX guidelines
(230 V)
26 mA
(230 V)
4 x 3.15 A, cos ϕ = 0,95
=
LELV, 16 V DC
=
=
SELV, 16 V DC
=
Spring connectors
EIB bus terminal (black/red)
Max. 5 minutes
Ah
4 x 3.15
Ah
0 °C to 45 °C
85 %
polycarbonate
CC-ABS
polycarbonate
180 x 255 x 63 mm (12 Te)
IP 20
II, corresponding to the installation
Typ 1.C micro interruption
2
4 kV
75 °C
CE by EN 60730-1
Der Motor Controller ist ein elektronisch betätigtes,
unabhängig montiertes Regel- und Steuergerät.
Durchgeschleifter Schutzleiteranschluss
Wirkungsweise Typ: 1
Verschmutzungsgrad: 2
Bemessungs-Stoßspannung: 4 kV
Temperatur der Kugeldruckprüfung: 75 °C
ANIMEO KNX EIB 4 AC MOTOR CONTROLLER.
A
[1]
B
[1]
min.:
63 mm
120 mm
140 mm
[3]
210 : 12 TE
Zeichnung sollte überarbeitet werden -> Linien zu dünn für Druck
2/12
REF. 5015473
-
[2]
[2]
1
[4]
1
90 mm
ANIMEO KNX EIB 4 AC MOTOR CONTROLLER.
2
Bus
Bus
> 10 cm
3/12