Construction:
Enclosure Rating:
Weight:
Approvals:
7ML19985GD61
Downloaded from
www.Manualslib.com
• combined sensor and electronics package
• sensor housing:
material:
mounting:
• electronics housing:material:
access:
• Type 4X / NEMA 4X / IP65
• 1.7 Kg (3.7 lb)
• CE*, FM CSA
NRTL/C
* EMC performance available on request.
• 3A (Sanitary model only)
The Probe – INSTRUCTION MANUAL
manuals search engine
PVDF or ETFE
threaded: 2"NPT, 2" BSP PF2
flanged:
flange adapter, threaded Probe to 3" ANSI, DIN
65PN10 and JIS 10K3B
sanitary:
4" FDA approved sanitary ferrule with integral sealing
ring c/w 304 stainless steel clamp (5 m model only)
PVC
hinged lid
22 mm (0.87") dia. `knock out' for conduit entrance, 2 places
6 screw terminal block for 2.5 mm
(16 ga) stranded wire max
2
2
(14 ga) solid wire / 1.5 mm