LEDs and buzzer (only 026390.10 and 026481)
The LEDs and the buzzer are controlled over a bus system.
The definition for each is specified in the main software and not at
the reader.
Dimensions (in mm)
vellow
green
red
ABC
DEF
1
2
3
GHI
JKL
MNO
4
5
6
PQRS
TUV
WXYZ
7
8
9
*
#
0
Mounting frame
62
86
Readers connected to ACS
Connection diagrams can be found in the documentations of the
corresponding AC controllers.
LED meaning with AC applications:
LED
Basic
After reading
colour
condition
a card
yellow
on
yellow
off
green
on
red
on
green
on
red
on
red
blinking
Additionally, the key and LED functions of the macro control of IQ
MultiAccess are valid (see separate manual "Supplementary functions
of IQ MultiAccess", P32205-46-0G0-xx).
8
Reader
82
60
ABC
DEF
1
2
3
GHI
JKL
MNO
4
5
6
PQRS
TUV
WXYZ
7
8
9
*
#
0
12
Reader incl. frame
12
24
Meaning
Operation / ready to read
Device is idle
PIN-Code or door code entry is
active
(only possible with readers with
RS-485 interface)
Permanently released
Permanently blocked
Door release
ID card not authorized
Read error
Readers connected to IDS
1.
Application
The readers can be operated with:
-
IK3 evaluation unit BUS-2
-
IK3 evaluation unit
conventional
-
Door controller module for MB
Data interface: RS-485 bus
A total of up to 4 readers (IK3 EU) or 2 readers (DCM) can be connected
to a single RS-485 bus. Mixed operation of different reader types on the
RS-485 bus is also possible.
See IK3 EU or DCM Mounting and Connection Instructions for details.
2.
Conditions
Firmware versions:
-
IK3 EU BUS-2
-
IK3 EU conventional
-
Door controller module
Supported data carrier (key):
3.
Functions
Arming/Disarming and/or AC function.
-
Only with data carrier (reader without keypad is operated with
toggle)
-
With PIN
and
data carrier *)
-
With PIN
or
data carrier *)
-
Hold-up code input also possible when disarmed.
*)
PINs up to 8 digits possible.
4.
Installation
(DIP switches and connection see page 7)
-
Activate RS-485 interface with DIP switches 7, 8.
-
Set RS-485 address with DIP switches 1 - 5.
-
Activate/deactivate RS-485 terminating resistance with DIP switches
9, 10 (depending on bus system, see IK3 EU/DCM Mounting and
Connection Instructions).
-
Set baud rate to 19200 baud with DIP switch 6.
-
Connect reader to the IK3 EU/DCM.
Important:
The power supply should be established via a separate
protected source, due to the high reader power consumption (e.g.
U_ext. from central control unit or separate power supply unit).
5.
Programming
5.1
Create reader
Create as IK3 operating unit with serial number 00000-00000.
Programming via BUS-2:
Several readers with the serial number 00000-00000 can be created
with IDCU firmware from version V05.09 and WINFEM Advanced
V01.xx onward.
Please note that no keypad code may be input in the case of readers
without a keypad, and "data carrier only" should be set for authorisation.
5.2
Authorisation of data carriers
The code given on the data carrier cannot be used, as codes different
to those used in the access control application are utilised in intrusion
detection technology. Data carriers must therefore be taught in.
- IK3 EU BUS-2 and Door controller module:
Data carriers are taught in with the aid of one-man revision
- F:402 "Check switching device"
and subsequent use of a learn master key
- F:308 "Learning monitor".
Learn master keys are created if necessary in these functions. The
code valid for intrusion detection technology is displayed by a taught-in
data carrier and can then be input as a learn master key code.
- IK3 EU conventional:
See Manual WINFEM Advanced
To authorize data carriers see Chapter 6. or 7.
firmware version IK3 EU/DCM)
(Item no. 023312 / 023312.10)
(
Item no.
023310)
(Item no. 023350)
from V04.xx
onwards
from V01.xx
onwards
from V10.xx
onwards
proX1/IK2
, e. g. 026370.00
(P03174-20-00x.xx).
(depending on