Herunterladen Inhalt Inhalt Diese Seite drucken

R Brake Option Installation - Siemens COMBIMASTER Bedienungsanleitung

Brems-optionen
Vorschau ausblenden Andere Handbücher für COMBIMASTER:
Inhaltsverzeichnis

Werbung

6

R BRAKE OPTION INSTALLATION

Case Size B R Brake Option Parts
B1
x6
B2
x1
B3
x1
CMOS components used in this
equipment are particularly
sensitive to static electricity.
Avoid touching these components,
or their printed circuit boards, with
bare hands or metal objects.
8
Downloaded from
www.Manualslib.com
Socket
Gate Drive Insulation with Label
PG9 Cable Gland
WARNING
CONTACTOR COIL
Fig. 4 R Brake Option Connection Diagram
manuals search engine
The R Brake Option fits in place of the
existing inverter cover. Prior to connection,
ensure that the mains contactor is
adequately suppressed using transient
suppressors.
R Brake Option Installation Process:
• Refer to Fig. 4.
• Connect the mains supply to the inverter
via a three phase contactor. Wire the
live supply to the contactor coil through
relay RL100, which is open when the
braking unit is not powered.
• Use a double insulated 2-core cable to
connect to the relay contacts CN101 (1)
and CN101 (2). The diameter of the
outer insulation must be in the range 4.5
to 6.0mm.
• Pass the cable through the PG9 gland
provided (part B3) and secure the gland
to form a tight fit around the cable.
• Connect a momentary action switch
across CN101 (2) and CN 101 (1) to
check the operation of the inverter. The
resistive brake option is powered from
the inverter and once powered, RL100
permanently powers the inverter.
LIVE SUPPLY
© Siemens plc 2000 ¦ G85139-H1731-U450-B1