Make sure that the room in which the stove is set up has at
least one door or window into the outside or is directly
adjacent to such a room. Other fireplaces and extractor
hoods must not be operated in the same room as the stove
Floor load capacity
Make sure that the load capacity of the supporting
construction is sufficient to carry the weight of the entire
unit, before the heating unit is installed.

Combustion air

Being the user of the stove you must take care of a sufficient
combustion air supply. Sealed-up windows and doors may
not allow a sufficient combustion air supply or disturb the
3.

CORRECT OPERATION OF YOUR STOVE

The operation is described in the enclosed user manual.
Accessories
You can obtain floor plates made of glass or steel, care products or the Heat Memory System for heat storage from your
certified dealer.
IMPORTANT:
Have defective parts replaced by your certified dealer. This will guarantee that your stove functions
properly and safely.
The fireplae must not be altered.
Maintenance
To clean the glass, please use a specialised product such as Thermohit glass cleaner. Lacquered surfaces are to be
cleaned only with a cloth (may be damp).
ATTENTION: Please avoid that the glass gasket comes into contact with water or detergents, as this will cause a curing
of the gasket and thus result in glass damage.
Only gaskets in good order ensure the proper function of your stove!
Cleaning
The stove, flue outlets and smoke pipes should be cleaned and inspected for deposits every year – if necessary more
often, e.g. after the cleaning of the chimney. The chimney also has to be cleaned regularly by the chimneysweeper. Your
chimneysweeper will inform you of the necessary inspection intervals. An expert should inspect the stove annually.
5
draught behaviour of your stove. Please ensure the
additional supply of fresh combustion air if necessary.
For details please consult your specialist retailer. Make
.
sure that the combustion air intakes are not blocked!
Stove pipe connection
For your own safety stringent laws apply for connecting
the stove pipes to the chimney. Your professional dealer
or distributor knows these laws. Please have your
certified retailer carry out the connection of your stove
Osca
.