Herunterladen Inhalt Inhalt Diese Seite drucken

Jung FRWM200 Betriebsanleitung Seite 60

Vorschau ausblenden Andere Handbücher für FRWM200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

radio groups form subgroups.
Alarm signals are passed only to the shared
radio group from an alarming subgroup and
trigger it. Alarm forwarding from the shared
radio group to the subgroup does not occur.
f Set up all the individual groups one after
another before connecting the individual
radio groups.
Flat 1
Corridor
Flat 3
Fig. 8
Example of shared radio group
Flat = subgroup
Corridor = shared radio group
Alarm direction = towards the shared radio
group
Operating Manual: FRWM200 – Smoke Alarm Device with Radio Link
60
Flat 2
Flat 4
6.1 Setting up radio group
The first device placed into service is Master,
and manages the installation of a radio group.
Note the following when setting up the master
device of a radio group:
(1) Push the splint pin sideways off activation
button.
(2) Push activation button flush.
Short acoustic signal
5 No other device is in learning mode.
(3) Press and hold the radio button with
splint pin until the LED signal lamp is
continuously on.
(4) Immediately release the radio button as
soon as the LED lights up.