INSTALLATION
Installation
9.1

Installing the safety assembly

f Fit the prospective safety assembly in the cold water supply
f
line of the appliance.
f Observe the information on the safety assembly (see chapter
f
"Installation / Safety / Information on the safety assembly").
f Observe the information in the installation instructions of the
f
safety assembly.
9.2

Appliance installation

f Mark out the holes for drilling with the installation template
f
supplied.
f Drill the holes and insert suitable rawl plugs.
f
f Secure the wall mounting bracket using suitable screws.
f
f Hang the appliance on the wall mounting bracket.
f
Note
Surplus cable can be stored in the cable compartment.
9.3

Water connection

Material losses
!
Carry out all water connection and installation work in
accordance with regulations.
Material losses
!
The appliance may lose its function.
f Never interchange the water connections.
f
f Set the flow rate (see safety assembly instructions).
f
Observe the maximum permissible flow rate with a
fully opened tap (see chapter "Installation / Specifi-
cation / Data table").
f Observe the maximum permissible pressure (see chapter "In-
f
stallation / Specification / Data table").
f Match up the colour coding on the water connections of the
f
tap and the appliance:
- R.h. side blue = "Cold water inlet"
- L.h. side red = "DHW outlet"
f Secure the water connections from the tap to the appliance.
f
Note
Ensure that the water connections are not kinked during
installation. Prevent any tensioning during installation.
www.stiebel-eltron.com
9.4

Power supply

WARNING ELECTROCUTION
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING ELECTROCUTION
When permanently connected to the power supply using
a dedicated junction box, the appliance must be able to
be isolated from the mains power supply by an isola-
tor that disconnects all poles with at least 3 mm contact
separation.
WARNING ELECTROCUTION
Ensure that the appliance is earthed.
Material losses
!
The voltage specified on the type plate must match the
mains voltage.
f Observe the type plate.
f
The following electrical connections are permissible:
Connection to a freely accessible
standard socket with matching
plug
Permanent connection to an ap-
pliance junction box with earth
conductor
Fixed power cable with the per-
manent connection set
Connection to a freely accessible
standard socket with matching
plug
Permanent connection to an ap-
pliance junction box with earth
conductor
Fixed power cable with the per-
manent connection set
The permanent connection set maintains the IP24 D protection
rating when converting the appliance.
SHU 10 SLi
SHU 10 SL GB
X
X
-
SH 10 SLi
SH 15 SLi SH 15 SL GB
3.3 kW
X
X
X
X
-
X
SHU 10 | SH 10 | SH 15 |
-
X
-
-
X
X
19