Herunterladen Diese Seite drucken
Honeywell TC809EA1035 Installationsanleitung
Honeywell TC809EA1035 Installationsanleitung

Honeywell TC809EA1035 Installationsanleitung

Monitormodul

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
Figure 1: TC809EA1035 Installed Without Rigid Mounting
Figure 2: Typical Circuit Configuration
COMPATIBLE
FIRE DETECTION AND
CONTROL
ALARM SYSTEM LOOP
PANEL
COMMUNICATION LOOP
(+)
(–)
ALL WIRING
SHOWN IS
SUPERVISED AND
POWER LIMITED
MONITORING LINE
0905 13
DOP-IOD005
EN54-17: 2005
HW-460-019
Honeywell Building Solutions, Honeywell House, Arlington Business Park, Bracknell, Berkshire, RG12 1EB, UK
INSTALLATION INSTRUCTIONS
(–)
(+)
)
( +
)
( –
7 8
6 7 8 9
6
9
5
5
10
4
11
4
3
12
3
13
2
2
1
14
1
0
15
0
VIOLET
YELLOW
EOL RESISTOR
47k EOL
INCLUDED
(ELR-47k)
TC809EA1035
Input / Output Device
Honeywell Control Systems Ltd
Honeywell House
Arlington Business Park
Bracknell, Berkshire
RG12 1EB, UK
TC809EA1035
MONITOR MODULE
BEFORE INSTALLING
This information is included as a quick reference installation guide. Refer
to the control panel installation manual for detailed system information.
If the modules will be installed in an existing operational system, inform
the operator and local authority that the system will be temporarily out
of service. Disconnect power to the control panel before installing the
modules.
NOTICE: This manual should be left with the owner/user of this equipment.
GENERAL DESCRIPTION
The TC809EA1035 monitor module can be installed in a single gang
junction box directly behind the monitored unit. Its small size and light
weight allow it to be installed without rigid mounting (see Figure 1). The
TC809EA1035 is intended for use in intelligent, two-wire systems where
the individual address of each module is selected using rotary decade
switches. It provides a two-wire initiating circuit for normally open contact
fire alarm and security devices.
Note: The TC809EA1035 serves only to relay information linked to a fire
signal to the control panel - it does not monitor the secondary line for
short circuit faults.
To ensure proper operation, this module should only be connected to a
compatible control panel.
SPECIFICATIONS
Communications Loop
Nominal Operating Voltage:
Average Operating Current:
Maximum Alarm Current
Monitoring Line
EOL Resistance:
Maximum Wiring Resistance:
Maximum Voltage to EOL:
Maximum Short Circuit Current: 217 µA
TO
NEXT
General
DEVICE
Temperature Range:
Humidity:
Dimensions:
Wire Length:
MOUNTING AND WIRING
NOTE: This module is intended to be wired and mounted without rigid
connections inside a standard electrical box. If rigid mounting is required,
then it may be affixed within the enclosure using cable ties and where
necessary suitable adhesive or screw type cable tie bases. The testing
and the approval was carried out with the rigid installation. The module
INCLUDED
should be mounted flat ensuring that it does not foul any other equipment
(47K OHMS
in the enclosure and care must be taken to ensure wires are not damaged
STANDARD -
during the installation.
ELR-47K).
1. Connect the red (+) and black ( – ) wires to the positive and negative
leads of the communication loop.
2. Connect the violet (+) and yellow ( – ) wires to a two-wire, normally
open monitoring line.
3. Install the specified EOL resistor value to terminate the monitoring
line. The EOL resistor for standard use is 47K Ohms – the other
resistors are for special use only.
4. Set the address on the module per job drawings.
5. Install the module in the desired mounting location.
E N G L I S H
I 56- 3992- 006
15-32 VDC
400 µA, 1 comm. every 5 seconds,
(Standard 47K EOL)
600 µA
47K Ohms Standard
1.5K Ohms
11 Volts
-10°C to 55°C
10% to 93% Non-condensing
33mm H x 71mm W x 15mm D
150mm minimum
I56-3992-006

Werbung

loading

Inhaltszusammenfassung für Honeywell TC809EA1035

  • Seite 1 It provides a two-wire initiating circuit for normally open contact fire alarm and security devices. Note: The TC809EA1035 serves only to relay information linked to a fire signal to the control panel - it does not monitor the secondary line for short circuit faults.
  • Seite 2: Prima Dell'installazione

    TC809EA1035 Dispositivo di ingresso / uscita Honeywell Control Systems Ltd Honeywell House 0905 13 Arlington Business Park DOP-IOD005 Bracknell, Berkshire EN54-17: 2005 RG12 1EB, UK HW-460-019 I56-3992-006 Honeywell Building Solutions, Honeywell House, Arlington Business Park, Bracknell, Berkshire, RG12 1EB, UK...
  • Seite 3: Antes De La Instalación

    TC809EA1035 Dispositivo de entrada y salida Honeywell Control Systems Ltd Honeywell House 0905 13 Arlington Business Park DOP-IOD005 Bracknell, Berkshire EN54-17: 2005 RG12 1EB, UK HW-460-019 I56-3992-006 Honeywell Building Solutions, Honeywell House, Arlington Business Park, Bracknell, Berkshire, RG12 1EB, UK...
  • Seite 4: Vor Der Installation

    Honeywell Control Systems Ltd ein. Honeywell House 0905 13 5. Installieren Sie das Modul am gewünschten Montageort. Arlington Business Park DOP-IOD005 Bracknell, Berkshire EN54-17: 2005 RG12 1EB, UK HW-460-019 I56-3992-006 Honeywell Building Solutions, Honeywell House, Arlington Business Park, Bracknell, Berkshire, RG12 1EB, UK...
  • Seite 5: Description Générale

    Honeywell Control Systems Ltd 0905 13 Honeywell House Arlington Business Park DOP-IOD005 Bracknell, Berkshire EN54-17: 2005 RG12 1EB, UK HW-460-019 I56-3992-006 Honeywell Building Solutions, Honeywell House, Arlington Business Park, Bracknell, Berkshire, RG12 1EB, UK...