Herunterladen Inhalt Inhalt Diese Seite drucken

Autofeed; Changing Cables; Changing Inner Drum - RIDGID K-45 Bedienungsanleitung

Abflussreinigungsmaschine
Vorschau ausblenden Andere Handbücher für K-45:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 55
K-45 Drain Cleaning Machine
drain cleaning compounds. Drain debris from drum by
tipping machine forward after every use to remove sedi-
ment and chemicals which can corrode cable.
To help prevent corrosion during storage, cables can be
coated with RIDGID Cable Rust Inhibitor. Once the cable
is clean and dry, pull the cable from the drum. While
manually feeding the cable back into the drum, wipe the
Cable Rust Inhibitor on the cable with a cloth.
Do not apply the Cable Rust Inhibitor to a rotating
cable. The cloth and your hand can become entangled in
the cable, and Cable Rust Inhibitor can be slung from ro-
tating cable.

AUTOFEED

Monthly or more often if needed, remove the AUTOFEED
mechanism from the AUTO FEED hand grip and clean and
lubricate.
1. Lift both AUTOFEED levers and push the cable
through the AUTOFEED.
2. Remove screw from AUTOFEED hand grip using
3
/
" allen wrench (Figure 12A) and remove the AUTO -
16
FEED mechanism (Figure 12B).
Figure 12A – Removing AUTOFEED Screw
Figure 12B – Removing AUTOFEED Mechanism From
Housing
12
3. Wipe or wash dirt and debris out of the AUTOFEED
mechanism and hand grip.
4. On the AUTOFEED mechanism, apply a small a -
mount of general purpose grease to the Lever arm
pivot points and roller bearing surfaces.
Reassemble in reverse order. AUTOFEED mechanism
will only fit into hand grip one way.
Changing Cable

Changing Inner Drum

The K-45 is supplied with an inner drum that fits snugly in-
side a two-piece drum that allows easy change-out of
cable. To access the inner drum feature:
1. Make sure handgrip is pulled forward to release the
cable from the chuck.
2. Loosen the four screws that hold the drum front to the
drum back about 3 full turns (do not remove) (Figure
13).
Figure 13 – Loosen 4 Drum Screws About 3 Full Turns,
But Do Not Remove
3. Separate the drum front from the drum back by hold-
ing the drum back and twisting the drum front counter
clockwise. (Figure 14).
Figure 14 – Twist Drum Apart
4. Remove the inner drum out of the drum back. Pull
cable back through drum front. With the AUTO FEED
999-998-285.09_REV. G

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

K-45af

Inhaltsverzeichnis