8.8

Cleaning the rinsing pump

T I P
It is often possible to remove soiling from the rinsing device and rinsing pump by
cleaning the rinsing device without the nozzle/nozzles.
Remove the nozzle/nozzles for cleaning so that the dirt particles are flushed out.
Preparatory work:
Remove the filter drum. (→ Removing the filter drum)
How to proceed:
 X
1. Undo the fastening device. To do this, unhook both rubber straps.
2. Lift the rinsing pump and remove the filter sock.
– Clean all parts in clean water.
8.9

Replacing the rinsing pump

Preparatory work:
Remove the filter drum. (→ Removing the filter drum)
How to proceed:
 Y
1. Undo the fastening device. To do this, unhook both rubber straps.
2. Loosen the hose clip and pull off the hose.
3. Take out the rinsing pump and replace.
– Disconnect the connection cable from the cable harness.
4. Fit the rinsing pump in the reverse order.
9.

Storage/overwintering

The unit is protected from frost (e.g. stored in a garage or other enclosure)
The unit can be operated as long as the water temperature does not go below +4 °C.
Set the interval for time-dependent cleaning to 20 minutes to avoid damage to the rinsing
device in the event of frost.
Install the control system in such a way that it is protected. The minimum operating
temperature of the control system is -10 °C.
The unit is not protected from frost (e.g. outdoor installation)
Take the unit out of operation at water temperatures below +8° C or, at the latest, when freezing
temperatures are to be expected.
Drain the unit as far as possible, clean thoroughly and check for damage.
Empty all hoses, pipes and connections as far as possible.
Leave the slide valves open.
Cover the container so that no rain water can enter.
Protect pipes and slide valves that are in contact with water from frost.
N O T E
The drum seal requires maintenance after winter or at the beginning of the pond season.
Remove the old grease, then apply new grease sparingly to the edge of the drum.