Technical Info
En
Mains water requirements
Minimum water flow pressure
Maximum water flow pressure
Water temperature
pH value
Iron content
Salt content
If these values or tolerances are exceeded or not reached, this may
damage the BestWater system.
A loss of warranty cannot be ruled out.
Stored pressure tank - internal
Height
Diameter
Volume capacity
Outgoing pressure
Connection
Initial pressure (without water)
* The flow pressure must be at least 2.5 bar and may not exceed 7.0
bar of overpressure. If the pressure is greater than 7.0 bar of over-
pressure, a pressure reduction valve must be installed.
** The consumption data may deviate from the values above depen-
ding on water pressure, water hardness, water flow temperature,
and room temperature.
58
Downloaded from
www.Manualslib.com
manuals search engine
2.5 bar*
7.0 bar*
4.4 °C - 40.5 °C
6.5 to 9.5
< 0.2 mg/l
< 2,000 ppm
330 mm
230 mm
approx. 5 l**
0.4 - 3.5 bar**
1/4"-JG quick connect
0.35 - 0.5 bar