Remove the old 20 µm pre-filter
cartridge and insert a new 20 µm
pre-filter cartridge. Turn the cart-
ridge finger-tight into the right filter
head.
Once the 20 µm pre-filter has been
replaced you can reattach the front
hatch to the BestWater system.
Now you can turn on the flow of wa-
ter to the appliance.
The system is now producing pu-
rified water. The pre-filter cart-
ridges contain the disinfectant hy-
Downloaded from
www.Manualslib.com
manuals search engine
Maintaining the BestWater System
drogen peroxide (H
through the unit after maintenance.
When draining later, the disinfectant
will disinfect all hoses that the puri-
fied water passes through.
After approx. 40 min. you must
drain all of the water through the
faucet. Wait long enough that the
water starts to trickle slowly out of
the faucet.
Fill the reservoir again and let the
water drain through the faucet one
more time.
Your semiannual filter change is
now complete and you can operate
the unit normally again.
Annual filter replacement
The pre- and post-filter units of the
Jungbrunnen 33-00 ULTIMATE must
be replaced every 12 months. Use
these images to help you with the
annual filter change, and follow the-
se steps:
O
), which flows
2
2