Herunterladen Inhalt Inhalt Diese Seite drucken

Nice FT210 Anweisungen Und Hinweise Für Den Installateur Seite 10

Optical device
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 45
17. To check the PSPE pressure sensitive device of
the FT210, push and release the sensitive edge as
shown in figure 23 and check that the L4 LED turns
off and that the L3 LED turns on and vice versa.
18. If this is the preferred program, connect the JP3
jumper on the TX so that the transmission changes
over to SLOW a few seconds after the movement
has finished.
19. If the operation in the previous point has been
performed; check that the transmitter changes over
to SLOW after the foreseen time has past (see JP2
in table 1). The transmission in the SLOW mode can
be recognised through four short flashes of the L1
LED followed by a pause.
20. Mechanically connect the leaf to the motor and
perform a manoeuvre of the gate.
In the meantime, check that the L2 LED turns off at
the beginning of the manoeuvre, indicating that the
vibration sensor test of the moving gate has been
performed correctly.
21. Perform various gate manoeuvres and check
that the opening and closing are correctly performed
without the inversion of the movement.
22. Perform further manoeuvres, and during the clo-
sure activate the optical presence sensor as indicat-
ed in point 15 and check that the foreseen action is
performed such as the inversion of the movement.
23. Perform additional manoeuvres and during the
closure activate the sensitive edge as indicated in
point 16 and check that the foreseen action is per-
formed such as the inversion of the movement.
24. The control of the FT210 optical presence sen-
sor (type D), according to the EN 12445 standard, is
performed with the 700x300x200mm test paral-
lelepiped with 3 black faces and 3 polished white or
mirrored faces as indicated in figure 24 and accord-
ing to chapter 7 of the EN 12445:2000 standard (or
enclosure A of prEN12445:2005).
25. The control of the PSPE pressure sensitive
device of the FT210 according to the EN 12445
standard, is performed by measuring the force at
the points foreseen in chapter 5 of the EN 12445
standard, if the hazardous situations, which have
been caused by the movement of the leaf, have
been safeguarded through the limitation of the
impact force (type C).
26. After verifying all the above points, remove the
damper filter from the glass panel on the RX receiv-
er as shown in figure 25.
27. Make sure that all casings of the various devices
are closed when testing is complete
Downloaded from
www.Manualslib.com
manuals search engine
23
24
25
10

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis