Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - Velleman DVM2000 Bedienungsanleitung

Sehr genaues true rms multimeter - 50000 zählungen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 55

6. Technical Specifications

Accuracy is specified for one year after calibration at operating temperatures of 18°C ~ 28°C with a relative humidity at 0% ~ 80%. Accuracy
specifications take the form of ± (% of rdg + number of least significant digits).
Environmental Conditions
Pollution Degree
Altitude
Operating Temperature
Storage Temperature
Fuse
Display
Over Range Indication
Low Battery Indication
Data Hold
Backlight
Power Supply
Dimensions
Weight
Accessories
AC Voltage/DC + AC Voltage
Range
50mV
500mV
5V
DVM2000
Downloaded from
www.Manualslib.com
1000V CAT III
2
< 2000m
0°C~30°C or 32°F~86°F (< 80% RH, < 10°C)
-20°C~60°C or -4°F~140°F (< 70% RH, batteries removed)
µA and mA, F630mA / 500V
A, F12.5A / 500V
99999
yes ("OL")
yes (
yes
yes
6 x AAA batteries
205 x 97 x 45mm
± 560g (with batteries)
2 x test leads, 1 x optical USB cable, PC-link software, 6 x AAA batteries, manual
Resolution
0.001mV
0.0mV
0.1mV
manuals search engine
)
40Hz~1kHz
± (0.5% + 40)
12
Accuracy
1kHz~10kHz
10kHz~20kHz
± (1% + 40)
± (2.5% + 40)
VELLEMAN

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis