Herunterladen Inhalt Inhalt Diese Seite drucken

Care, Maintenance And Disposal; Safety; General; At Every Start-Up - Fronius TransPocket 3500 Remote Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für TransPocket 3500 Remote:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Care, maintenance and disposal

Safety

Work that is carried out incorrectly may result in serious injury or damage to prop-
erty.
► The activities described below must only be carried out by trained and qualified per-
► Observe the safety rules in the power source Operating Instructions.
An electric shock can be fatal.
Before opening the unit
► Turn the mains switch to the "O" position
► Unplug the device from the mains
► Put up an easy-to-understand warning sign to stop anybody inadvertently switching it
► Using a suitable measuring device, check to make sure that electrically charged com-
An inadequate ground conductor connection can cause serious injury or damage.
The housing screws provide a suitable ground conductor connection for earthing the hous-
ing.
► The housing screws must NOT be replaced by any other screws that do not provide a

General

Under normal operating conditions, the device requires only a minimum of care and main-
tenance. However, it is vital to observe some important points to ensure the device remains
in a usable condition for many years.

At every start-up

-
-
NOTE!
Air inlets and outlets must never be covered, not even partially.

Every 2 months

-
WARNING!
sonnel.
WARNING!
back on again
ponents (e.g. capacitors) have discharged
WARNING!
reliable ground conductor connection.
Check the mains plug, mains cable and ground (earth) connection for damage
Check that there is a gap of 0.5 m (1 ft. 7.69 in.) all around the machine to ensure that
cooling air can flow and escape unhindered
Clean the air filter (if fitted)
75

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis