Seq. no.
A11
A12
A13
A14
A15
A16
A17 - A32
A33 - A40
A41 - A48
A49 - A56
A57 - A64
A65 - A112 Not used
A113 -
A224
A225 -
A336
A785 -
A896
70
Signal designation
Process active
Arc stable
Not used
Power source ready
Communication ready
Not used
Not used
Voltage actual value
High Byte
Low Byte
Current actual value
High Byte
Low Byte
Same signal assignment as
A01 - A112 for power
source no. 2
Same signal assignment as
A01 - A112 for power
source no. 3
.
:
:
Same signal assignment as
A01 - A112 for power
source no. 8
Signal description
0
Power source not active
1
Power source delivering power
(open circuit voltage or welding power)
0
Welding current < 5 A or
welding voltage < 10 V
1
Welding current > 5 A and
welding voltage > 10 V
0
Power source not ready => see "Trouble-
shooting" section
1
Power source ready
0
No communication between KL6021 and
power source
1
Communication between KL6021 and pow-
er source OK
Value of actual welding or open circuit volt-
age in 0.1 V steps
Value of actual welding current in 0.1 A
steps