Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; The Battery Symbol Lights Up; Operating Hours Are Not Counted Completely; Too Many Operating Hours Are Counted - Agreto VibroCounter II Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

AGRETO VibroCounter II

10 Troubleshooting

10.1 The battery symbol lights up

The batteries need to be replaced, follow these steps:
Remove the seal and the seal wire.
Remove the housing and remove the meter.
Remove the old batteries and dispose them properly.
Insert 2 new AAA batteries into the device in the specified direction.
Mount the counter again on the mounting plate.
Seal the device again with a new seal wire and a new seal.

10.2 Operating hours are not counted completely

The movements or vibrations on the machine are probably relatively low, so that
the necessary intensity for the count is not reached.
Set the parameter SENS down so that the counter triggers even with minor
movements.
To hold longer periods of rest during operation, set the parameter hOLd
upwards.

10.3 Too many operating hours are counted

Perhaps the machine is exposed to light movements at standstill, which are
recorded as operating hours.
Set the parameter SENS upwards so that the counter only triggers for
larger movements
To prevent idle phases from being counted during operation, set the hOLd
parameter down.

10.4 Damage to the device

Contact the manufacturer or your dealer.
© AGRETO electronics GmbH
page:12

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis