Herunterladen Inhalt Inhalt Diese Seite drucken

Assembly; Positioning Of The Meter; Fixing The Mounting Plate - Agreto VibroCounter II Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

AGRETO VibroCounter II

7 Assembly

7.1

Positioning of the meter

Choose the most protected, yet accessible mounting location on the machine.
The installation position is not relevant for the operation of the meter.
7.2

Fixing the mounting plate

On delivery, the meter is mounted on the
mounting plate. Disassemble the meter from
the mounting plate.
Hold the mounting plate in the desired
position to the desired mounting position.
Use the mounting plate as a template and
mark the 2 holes with a pin.
Hit one notch each with a grain.
Drill the 2 holes with a 4.2 mm diameter drill.
Deburr the 2 holes.
Use a M5 screw tap to cut a thread in each hole.
Use the 2 M5x25 allen screws and the 2 aluminum washers and screw the
base plate to the machine. Note that the sealing surface of the base plate
is pointing towards the meter.
© AGRETO electronics GmbH
page:8

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis