9. Specifications
Electrical connections
Description
Circular connector M12 x 1, code A, 4-pin
Deutsch connector DT04-3P, 3-pin
Deutsch connector DT04-2P, 2-pin
Deutsch connector DT04-4P, 4-pin
Delphi connector Metri-Pack series 150, 3-pin
Cable outlet, IP6K9K, 2- or 3-wire
AMP Superseal connector 1.5 series, 3-pin
AMP Seal 16 connector, cone, code A, 3-pin
AMP Micro Quadlok System connector, code A,
3-pin
AMP Econoseal J Mark II series connector,
3-pin
VW connector, code I, 4-pin, 2 rows
1) The stated ingress protection only applies when plugged in using mating connectors that have the appropriate
ingress protection.
For special models MH-40000 or special version MH-4, other technical specifications apply. Please note the
specifications stated on the order confirmation and the delivery note.
For further specifications see WIKA data sheet PE 81.63 and the order documentation.
WIKA operating instructions pressure sensor, model MH-4
Ingress
Permissible ambient
protection
temperature
1)
IP67
-40 ... +125 °C
[-40 ... +257 °F]
IP6K9K
-40 ... +110 °C
[-40 ... +230 °F]
With cULus approval:
-40 ... +85 °C
[-40 ... +185 °F]
IP67
-40 ... +125 °C
[-40 ... +257 °F]
EN