4.5 ACTIVATION

FRIGOMAT declines all and any liability for damage caused by failure to comply with the
following indications. This lack of compliance causes the warranty to terminate.
Connection of the machine to the water mains must be performed in compliance with
national regulations of the Country where the machine is installed.
To commission the machine, take it to the place of use, checking that requested for its
installation:
1. Electrical power supply 3 phases + neutral + earth (5 wires);
2. Cold water mains supply (13° - 20°C, only water mod.);
3. Condensate water drain (only water mod.).
 Make sure the appliance is positioned on a solid, stable, flat and levelled surface.
 Block the machine by acting on the relevant brake lever on the rear wheels.
 Leave at least 10 cm from the side panels and 30 cm from the rear panel between the
machine and the walls or other obstacles. For machines with water condensation, the
distance between the wall and the rear panel must be 10 cm.
 Check the exact correspondence between the voltage and power of the mains
compared to the values carried on the data plate applied on the rear panel.
 Connect the machine to the electrical power supply system. Install an omnipolar master
switch upstream the appliance with minimum contact opening of 3 mm of adequate
power, with a fuse and circuit breaker protective system. Use an approved interlocking
plug to allow only the open circuit to connect and disconnect.
 The cable must be well laid, without being rolled-up or overlapped. It must not be
exposed to blows or tampering. It must not be in the vicinity of liquids or water and heat
sources. It must not be damaged in any way. If so, before connecting the machine to
the mains, have it replaced by qualified personnel with another having a 5G4 H07RN-F
(400 V version), 5G6 H07RN-F (220 V / 3 version) cross-section.
 For safety purposes, make sure the earthing system to which the machine plug is
connected is compliant with standards and is perfectly efficient.
9 - ENGLISH