5. Changing and Saving Temperature Set Value
When SET button pressed ''S'' led will
be active and temperature set value will
be displayed.
When SET button pressed
temperature set value can be saved.
Temperature set value parameter ( Default = 37.4
Temperature set value, can be programmed between minimum temperature set value
maximum temperature set value
i
5.1 Programming Mode Parameter List
Downloaded from
www.Manualslib.com
Main Operating Screen
PAUSE
ü ü
ü
SET Value Screen
PAUSE
ü ü
ü
If no operation is performed in temperature set value changing mode for 5 seconds, device
turns to main operation screen automatically.
Temperature Unit Selection Parameter ( Default = 0 )
°C selected.
°F selected.
Decimal Seperator Enabling Parameter
None.
Only Temperature parameters with decimal seperator.
Note : When value of C-F or Pnt parameters are changed , the values of Set ,hSt, Suh,
SUL ,oFt, Ast, ALh,AUL and Auh parameters should be changed accordingly.
Temperature Control Selection Parameter On/Off or PID ( Default = 0 )
On - Off selected.
PID selected.
Note: If this parameter is select 0, PID parameters will be not observed.If this parameter
select 1,
parameter will be not observed.
Auto Tune (Limit Cycle Tuning)
Device does not do(Limit cycle Tuning) operation.
Device does operation.
manuals search engine
°C
)
.
( Default = 1 )
Selection Parameter ( Default = 0 )
SET Value Screen
Temperature set value can
be changed with increment
and decrement buttons.
Main Operating Screen
''S'' will be inactive and goes
back to main operation screen.
PAUSE
ü ü
ü
PAUSE
ü ü
ü
and
8