Herunterladen Inhalt Inhalt Diese Seite drucken

Vacuum Pump; M1) Oil Top-Up. M2) Oil Change - MasterCool 69789-220 Gebrauchsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 76
Switch on the machine. From the CALIBRATION MENU:
Select BOTTLE TEMPERATURE and the following screen is displayed:
Check that the temperature shown on the display is that also read on the external
thermometer. If necessary, press START to modify the machine value:
Type in the temperature read on the digital thermometer and press ENTER to confirm.
Replace the temperature probe on the bottle.

VACUUM PUMP

Perform the operations listed below on a routine basis in order to ensure good operation of the
vacuum pump:
M1) Oil top-up.
M2) Oil change.
When refilling or replacing the pump oil, use only the oil recommended by the manufacturer.
Contact your retailer for information concerning the correct type of oil.
M.1) Oil top-up
This operation must be performed when the level of the oil falls to less than half on the indicator
(4) (refer to Figure 10). NOTE: in order to correctly check the oil level, run the pump for at least
1 minute (running a vacuum procedure in the hose for 1 minute) so that the oil fluidifies. Check
the oil level when the pump stops. To refill the oil, perform the steps listed below in the order
given. Disconnect the MACHINE from the mains supply. Locate the oil cap (2) and screw it
completely off. The oil must be added through the hole in which the oil cap was lodged (2). Add
oil a little at a time, waiting for the level to rise before each successive addition, until the oil level
is about ½ cm above the red mark on the indicator (4). Replace the oil cap (2) and tighten
down.
M.2) Oil change
The vacuum pump oil must be replaced every 150 working hours and in any case every time
the refrigerant filters are replaced. The oil must also be replaced whenever it changes color
due to absorption of humidity. Before beginning the oil change procedure, procure a container
of at least 500 cc capacity in which to collect the used oil. The pump contains about 500 cc of
oil. Use only the oils recommended by the manufacturer (consult your retailer).
1) Disconnect the machine from the mains supply.
Downloaded from
www.Manualslib.com
INSTRUCTIONS MANUAL
BOTTLE SCALE
OIL SCALE
A/C PRESSURE TR.
BOTTLE TEMPERATURE
BOTTLE TEMPERATURE
XX.X °C
START to change
STOP to exit
BOTTLE TEMPERATURE
XX.X °C
XXX.X °C
Press START
manuals search engine