6. CleanSpace2

For added safety, all CleanSpace2
Protection Circuit Module (PCM) to ensure the batteries are protected against over-charge and over-discharge.
The following precautions must be followed during use:
Avoid mechanical shocks or impacts from any sharp or hard objects
Do not use or place the Respirator or Endurance Packs in extreme heat, such as in direct sunlight, near
heat sources, etc. The battery will be damaged if its temperature goes above +100°C. Note: The
CleanSpace2™ will stop functioning if its internal temperature rises above +60°C or below -10°C
Do not dispose of the Respirator or Endurance Packs in fire
Do not use CleanSpace2™ Respirator in heavy rain, or allow it to get wet or immersed in liquid
Do not disassemble the Power Unit case, there are no user serviceable parts inside
Do not use the CleanSpace2™ Respirator if there are any signs of severe mechanical damage

7. Cleaning CleanSpace2

We recommended that you clean your Respirator after every use. The mask, Power Unit, neck pad and harness
need to be cleaned separately. Disassemble the mask, neck pad and harness from the Power Unit before cleaning.
CleanSpace2
Power Unit and masks.
WASHING THE MASK
There are three (3) methods for cleaning the CleanSpace
covering the exhalation valve leaf. To remove the valve cap, find the small inlet located under the lower, inside edge
of the valve (see diagram). Use your finger nail to unclip and push up the valve cap. The valve cap is easily fitted
back by placing the cap with the clip aligned to the inlet on the valve seating and pushing down. The valve cap will
gently snap back into place.
1. CleanSpace2
CleanSpace2
ideally suited for silicone face pieces.
To clean the exhalation valve, remove the valve cap (using the instructions above), gently wipe the leaf
edge. Replace the valve cap before use.
2. Hand wash in warm soapy water
Wash the mask thoroughly with a mild detergent in warm water (<50°C)
A soft brush or sponge can be used to remove any stubborn dirt or grit
Downloaded from
www.Manualslib.com
Battery Information (continued)
internal batteries and CleanSpace2
IN THE EXTREMELY RARE CIRCUMSTANCE WHERE THE BATTERY
IS DAMAGED AND ELECTROLYTE COMES IN CONTACT WITH EYES,
FLUSH WITH WATER IMMEDIATELY AND SEEK URGENT MEDICAL ATTENTION
cleaning wipes are recommended as a simple and effective method of cleaning the CleanSpace2
Non-Alcohol Wipes for face piece
Cleaning Wipes are impregnated with benzalkonium chloride, a bactericidal solution
manuals search engine
mask. Before washing the mask, remove the valve cap
10
10
Endurance Packs have a built-in