ENGLISH
E18: VCV ERROR
(Only GAS ovens)
DESCRIPTION
VCV does not respond to the gas control and the speed is not stable.
CONSEQUENCE
It is only possible to operate in Convection mode
E19: VCC2 ERROR
DESCRIPTION
VCC2 does not respond to the gas control and is at maximum speed.
CONSEQUENCE
The oven is completely disabled.
E20: VCC2 ERROR
DESCRIPTION
VCC2 does not respond to gas control and has stopped.
CONSEQUENCE
The oven is completely disabled.
E21: VCC2 ERROR
DESCRIPTION
VCC2 does not respond to the gas control and the speed is not stable.
CONSEQUENCE
The oven is completely disabled.
E22: TEMP. HIGH
DESCRIPTION
The controller NTC exceeds 70ºC
Text: E22: TEMP. HIGH""
CONSEQUENCE
The oven is completely disabled.
E23: ERR FLUEPIPE
DESCRIPTION
Fluepipe motor faulty
CONSEQUENCE
The oven is completely disabled.
E24: BMF CHAMBER
DESCRIPTION
Communication error. The chamber card does not respond.
CONSEQUENCE
The oven is completely disabled.