Herunterladen Inhalt Inhalt Diese Seite drucken

Adding Salt To The Pool Water; Calibrating The Ph Detection Electrode; Calibrating The Orp (Chlorine) Detection Electrode - Teuco X762 Gebrauchsanweisung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 68
EN

ADDING SALT TO THE POOL WATER

Add 500 g normal salt (NaCl) for human consumption when the display reads "LOW
SALT" and leave the minipool operating for around 30 minutes.
Make sure that the display no longer reads "LOW SALT". If this is not the case, repeat the
operation (see chapter ALARMS).
At regular intervals of no more than one month, compare the pH value of the water in the
pool with that detected by the automatic treatment system, using the kit supplied.
If the pH values differ by more than 0.3 – 0.4, then the pH detection electrode will need to
be readjusted.
Contact your nearest Authorized Technical Assistance Centre (see list attached).
At regular intervals of no more than one month, check the value for the chlorine in the
water.
In the event of excess or insufficient chlorine, increase or reduce the ORP value as
required within the range permitted by the device.
If in this case, too, the amount of chlorine is not regular, it may be necessary to adjust the
ORP probe.
Contact your nearest Authorized Technical Assistance Centre (see list attached).
36
H DETECTION ELECTRODES
AUTOMATIC WATER TREATMENT KIT

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis