16.
esetting data to zero
16.1
Zero setting of dosers alarm
1) Turn the programming switch to ON;
2) Use the MODE key
3) Press the key
4) Press the UP ARROW key
16.2
Resetting selection count to zero
1) Turn the programming switch to OFF;
2) Keep the PROG key
3) Turn the programming switch to ON;
4) Press the key
5) Press the UP ARROW key
i
The above procedure allows resetting to zero of doses while leaving the total counts of the machine
unchanged (life cycle of the machine).
W
17.
arnings
1.0 atm
120°C
BOILER filling
1.1 atm
120°C
filling timeout
doser alarm
reg. softener
i
If the machine will not work call technical assistance.
to scroll the menu until (see chapter 15);
to reset to zero;
for at least 3 seconds to confirm reset to zero.
pressed for 5 seconds;
to reset to zero;
for at least 3 seconds to confirm reset to zero.
cause
Boiler filled with water when using the
machine for the first time or when refilling
to reach the water level.
Normal activation of time limit upon first
filling of boiler with water.
Time for filling the boiler with water longer
than expected.
Fault of the volumetric electronic control
Lack of water softener regeneration.
solution
Wait for the boiler to be completely filled.
Switch the machine off and back on again.
Make sure the water mains cock is opened.
Switch the machine off and on again . If the
warning is still on after a few attempts, call Te-
chnical Assistance.
Stop delivery by pressing the dose key.
Call the Technical Assistance.
Carry out the water softener regeneration. To
turn off the warning turn the programming
switch to ON and press the 4 display keys
imultaneously for 5 seconds
dosers alarm
021 007 000
reset counting ?
press + 3 sec.
doser alarm
000 000 000
total coffees
00000000
reset counting ?
press + 3 sec.
data reset
33