Herunterladen Inhalt Inhalt Diese Seite drucken

Error Messages (Expert); Defective Uvc Pipes! (Expert); Weak Uvc Pipes! (Expert); Defective Pump, Outlet! (Expert) - Helios KWL HB serie Montage- Und Betriebsvorschrift

Kwl-hygrobox
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation and Operating Instructions

19. Error messages (Expert)

19.1 DEFECTIVE UVC PIPE! (EXPERT)
UVC-Röhre defekt!
19.2 WEAK UVC PIPE! (EXPERT)
UVC-Röhre schwach!

19.3 DEFECTIVE PUMP, OUTLET! (EXPERT)

Pumpe, Abl.defekt!

19.4 HUMIDITY TOO HIGH! (EXPERT)

Feuchte zu hoch!
KWL Hygrobox KWL HB.. EH/WW
In the case of error messages, an alarm
sounds which can be deactivated by
pressing or turning the <Scroll wheel>.
The error messages are shown in the
display. After each error message (with
the exception of Service and Filter
change), the water is drained and the
air humidification unit is switched off.
The error messages can be deleted by
pressing the "Back" button for 3 seconds
34
or in the Service menu under the Delete
Fault Yes< item. After that, the air hu-
midification unit re-enters the operating
mode.
The expert/service department should
be informed in case of error messages.
• The UVC pipe is monitored continuously. A failure is de-
tected automatically. The UVC pipe should be changed
by the expert/service department every two years. Only
original UVC pipes should be used. In case replica com-
ponents are used, the warranty extinguishes and a gua-
rantee of function cannot be provided.
• Fault rectification only by the expert: Change the UVC
pipe under observance of the safety measures (see sec-
tion 20, page 37).
• During operation the UV radiation decreases continuous-
ly. As soon as the radiant power drops below 20% of the
calibrated value, this fault message is displayed (see ad-
jacent image).
• Fault rectification only by the expert:
Open the device under observance of the safety measu-
res and remove deposits in the tank, on the rotor, on the
UVC pipe etc. using descaling agent and then rinse them
with water (see section 20. Maintenance).
• If the floating switch actuates during the water replace-
ment, the existing water cannot be drained.
• Fault rectification only by the expert:
Check the pump, outlet and floating switch.
• If the relative humidity exceeds the reference value by
25% for a period of 25 hours, the water is drained and
the unit switches off.
• Fault rectification only by the expert:
Check the inlet value and integrated humidity sensor.
EN

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Kwl hb 250 ehKwl hb 250 s wwKwl hb 500 s ww

Inhaltsverzeichnis