Installation and Operating Instructions
EN
8.3 SETTINGS
Temperatur 21°C<
Feuchte
Service
Interner Fühler
Externer Fühler
Ext. Fühler nich t an gesch lossen!
Info
Fehler löschen
Experte
9. Operating statuses
9.1 AUTOMATIC ACTIVATION/DEACTIVATION AUTUMN/SPRING (AUTO STANDBY)
a uto S TANDBY
REGELUNG EIN
KWL Hygrobox KWL HB.. EH/WW
50%<
<
Temperatur
<
Feuchte
Ext. Fühler
<
g
Softwareversion
<
V 1.0
01.09.08
Fehler
<
löschen?
Kennzahl?
<
------
• The parameter Temperature is used to set the air tem-
perature at the outlet of the air humidification unit bet-
ween 15 °C and 25 °C in intervals measuring one degree
each. The factory setting is preset at 21 °C.
• The parameter TemperaturE (E = external temperature
sensor), is used to set the desired air temperature at the
external sensor between 15 °C and 25 °C in 1° intervals.
• The parameter Humidity is used to set the target outlet
air humidity at a level between 40 % and 60 % of relati-
ve humidity, in intervals of five per cent each. The factory
setting is preset at a relative humidity of 50 %.
• The menu item Service displays information about the
operational status.
• Internal sensor shows the currently measured air tem-
21°C
perature and the relative humidity at the air outlet of the
50%
air humidification unit.
• External sensor indicates the currently measured air
21°C
temperature at the external temperature sensor.
• If a sensor is not connected, the following will be dis-
played (see adjacent image).
• The installed software version is shown under Info.
• Error messages, which appear in the Info line of the dis-
Ja<
play, are deleted using the Delete Fault Yes< function.
Nein
• With Expert, you can access the next lower menu level by
entering a code. This parameter can be opened only by
the respective expert.
• The air humidification unit switches on when the air hu-
midity is too low (Autumn) and off when the air humidity
is too high (Spring). The following appears on the display
( see adjacent image ).
• If the evaporative power within 24 hours is less than one
litre, the device switches off (Auto STANDBY).
• If the humidity undershoots the set humidity by 7% for a
period of 24 hours, the air humidification unit switches on
again.