DUOX PLUS has the option of configuring the call from the
General Input panel with 4 or 6 digits. The normal operation of
the system is equivalent to 6 digits (explained above), while if 4
digits are selected, those corresponding to the sub-block are not
entered when dialling.
For example, to call apartment 24 in sub-block 0 and block 1 the
following would be dialled:
- 6 digits: 10024.
- 4 digits: 124.
If an unexpectedly short code is entered, this is filled in with '0's
on the left hand side, meaning that there is no need to manually
enter '0's on the left hand side.
IMPORTANT NOTE: Configuration of parameters by the installer. View via
the QR code available on the back of the amplifier or at www.fermax.com.
- PUSHBUTTON panel via voice assisted configuration code 970048
- DIRECT panel (with keypad), see Configuration Table, code 970052
4

Panel Connectors:

• System connection terminals:
B,B,B: DUOX Bus: power supply, data, audio and video.
C, NO, NC: Relay dry contact (Max 2A@30Vdc).
+12: output12 Vdc-250mA (maximum 500mA for 100 seconds).
BS, -: exit button.
SP, -: door sensor input.
P1-P2: button connections.