1.2 Other important notes

A blue or grey circle with a white graphical
symbol indicates that an action must be
taken.
A red or grey circle with a diagonal bar,
possibly with a black graphical symbol,
indicates that an action must not be taken
or must be stopped.
If these instructions are not observed, it
may result in malfunction or damage to the
equipment.
Tips and advice that make the work easier.

2. Receiving the product

2.1 Transporting the product

WARNING
Harm of body
Death or serious personal injury
- Stack maximum two pallets together
under transportation.

3. Installing the product

Installation must be carried out by
specially trained persons and according to
local regulations.
If not already integrated, a water trap (emission trap)
must be fitted in all inlets.
Conlift is not designed for outdoor use.

3.1 Mechanical installation

See also the quick guide supplied with Conlift.
When installing Conlift, observe the following:
The condensate must run freely into the lifting
station.
The cooling slots in the motor cover must not be
covered.
The lifting station should be easily accessible in
order to facilitate maintenance.
The lifting station must be installed in a
well-illuminated and -ventilated room.
The lifting station is protected against splashing
water (in compliance with IP24).
6
3.1.1 Alarm PCB
The accessory Alarm PCB incorporates a
printed-circuit board (PCB) enabling additional
functions when the level in the tank reaches the
alarm level.
The contact on the PCB can be set to two positions:
Position 1: The pump is started, and an acoustic
alarm is generated.
A: The alarm cable is not connected to the
condensate source or an external alarm. The
condensate source is not switched off.
B: The alarm cable is connected to the condensate
source or an external alarm. The condensate source
is switched off. See section
condensate source or external
Position 2: The pump does not start, and an
acoustic alarm is generated.
A: The alarm cable is not connected to the
condensate source or an external alarm. The
condensate source is not switched off.
B: The alarm cable is connected to the condensate
source or an external alarm. The condensate source
is switched off. See section
condensate source or external

3.2 Electrical connection

Electrical connection must be carried out
by an authorized electrician.
WARNING
Electric shock
Death or serious personal injury
- Make sure that the protective earth from
the socket outlet is connected to the
protective earth in the pump.
Make sure that the plug has the same
PE connection system as the socket
outlet or else use a suitable adapter.
The product must be connected to a main
switch with a minimum contact gap of 3
mm in all poles.
Check that the supply voltage and frequency
correspond to the values stated on the nameplate.
We recommend to provide the permanent installation
with an earth leakage circuit breaker (ELCB) with a
tripping current < 30 mA.
The power supply cable has a Schuko plug or a free
cable end. The cable has a length of 2 metres.
3.2.1 Cable to
alarm.
3.2.1 Cable to
alarm.